[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] RE: iSCSI: Representing iSCSI devices on FC fabrics
Correction - the company_id is 24 bits, not 20 bits.
EUI-64 = (MSB) { 24-bit company_id,
40-bit vendor specified } (LSB)
FC WWN = (MSB) { 4-bit NAA field,
24-bit company_id,
36-bit vendor specified } (LSB)
(for the IEEE Registered NAA type)
> -----Original Message-----
> From: Elliott, Robert
> Sent: Friday, November 16, 2001 9:33 AM
> To: ips@ece.cmu.edu
> Subject: RE: iSCSI: Representing iSCSI devices on FC fabrics
>
>
> Beware than a FC WWN is not the same as an EUI-64. They're both based
> on the IEEE OUI/company_id, but the FC WWN uses the 4 most significant
> bits for a "Name Address Authority" field and has 4 fewer
> bits available
> in the vendor specified portion.
>
> EUI-64 = (MSB) { 20-bit company_id,
> 44-bit vendor specified } (LSB)
>
> FC WWN = (MSB) { 4-bit NAA field,
> 20-bit company_id,
> 40-bit vendor specified } (LSB)
> (for the IEEE Registered NAA type)
>
> ---
> Rob Elliott, Compaq Server Storage
> Robert.Elliott@compaq.com
Home Last updated: Mon Nov 19 09:17:42 2001 7850 messages in chronological order |